BCXDM - AROMATIC 150, SOLVESSO 150

  • MSDS: BCXDM
  • Manufacturer: EXXON CO USA
  • Product Name: AROMATIC 150, SOLVESSO 150
  • National Stock Number: 8010-00-068-1099
Product Identification

Product ID:AROMATIC 150, SOLVESSO 150
MSDS Date:02/09/1988
FSC:8010
NIIN:00-068-1099
MSDS Number: BCXDM

Responsible Party
EXXON CO, USA
HOUSTON, TX 77252-2180
US

Emergency Phone: 713-221-3424

Info Phone: 713-656-5949

Cage: GO864

Contractor
EXXON COMPANY U.S.A.
2180 HOUSTON, TX 77252-2180 US

Telephone: 713-656-5949 / 713-656-3424

Cage: 29700

Ingredients

SOLVENT NAPHTHA; (HEAVY AROMATIC SOLVENT NAPHTHA

CAS: 64742-94-5

RTECS: WF3100000

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: N/K


NAPHTHALENE (SARA III)

CAS: 91-20-3

RTECS: QJ0525000

OSHA PEL 10 PPM/15 STEL

ACGIH TLV: 10 PPM/15 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ENTERED/MAY ENTER SEWERS, WATERCOURSES, OR EXTENSIVE

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


REGS. CONTINUE TO OBSERVE PRECAUTIONS FOR VOLATILE,

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


PROPERLY BUNGED & PROMPTLY RETURNED TO DRUM

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


AN ENVIRONMENTALLY SAFE MANNER & I/A/W GOVERNMENTAL

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


ADMIN REGS, ANSI Z49.1, & OTHER GOVT & INDUSTRIAL

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


OR OTHER CONTEMPLATED OPERATIONS.

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50(ORAL RAT) >5G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HLTH STUDIES HAVE SHOWN MANY PETRO
HYDROCARB & SYNTH LUBRICANTS POSE POTNTL HUMAN HLTH RISKS WHICH MAY
VARY FROM PERSON TO PERSON. AS A PRECAUT, EXPOS TO LIQS, VAPS,
MISTS/FUMES SHOULD BE MINIMIZING. PROD CONT EYES MAY CAUSE EYE
IRRIT. PROD HAS LOW ORDER OF ACUTE ORAL & DERMAL TOX, BUT MINUTE
AMTS (EFFECTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ASPIRATED INTO LUNGS DURING
INGEST/VOMIT MAY CAUSE MILD TO SEV PULM INJURY & POSSIBLY DEATH.
HIGH VAP CONC (>/APPROX. 1000 PPM) ARE IRRITATING TO EYES & RESP
TRACT, MAY CAUSE HDCHS & DIZZ, AR E ANESTHETIC, & MAY HAVE OTHER
CNS EFFECTS INCLUDING DEATH.
Medical Cond Aggravated by Exposure:PETROLEUM SOLVENTS/PETROLEUM
HYDROCARBONS - SKIN CONTACT MAY AGGRAVATE AN EXISTING DERMATITIS.

First Aid

First Aid:EYES:FLUSH W/CLEAR WATER FOR 15 MINS OR UNTIL IRRIT SUBSIDES.
IF IRRIT PERSISTS, CALL PHYS. SKIN:REMOVE ANY CONTAMD CLTHG & WASH
SKIN THORO W/SOAP & WATER. INHAL:IF OVERCOME BY VAP, REMOVE FROM
EXPOS & CALL PHYS IMMED. IF BRTHG IS IRREGULAR/HAS STOPPED, START
RESUSCITATION, ADMIN OXYG, IF AVAIL. INGEST:DO NOT INDUCE VOMIT;
CALL PHYS IMMED.

Fire Fighting

Flash Point Method:TCC
Flash Point:145F,63C
Lower Limits:0.8%
Upper Limits:7%
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEM, CO*2 &
VAPORIZING LIQ TYPE EXTING AGENTS MAY ALL BE SUITABLE FOR EXTING
(SUPDAT)
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . USE
WATER TO KEEP FIRE-EXPOSED CNTNRS COOL. IF LEAK/SPILL HAS NOT
IGNITED, USE WATER SPRAY TO DISPERSE (SUPDAT)
Unusual Fire/Explosion Hazard:MINIMIZE BREATHING GASES, VAPOR, FUMES OR
DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:SHUT OFF & ELIM ALL IGNIT SOURCES. KEEP PEOPLE
AWAY. RECOVER FREE PROD. ADD SAND, EARTH/OTHER SUITABLE ABSORB TO
SPILL AREA. MINIMIZE SKIN CONT. VENT CONFINED SPACES. OPEN ALL
WINDOWS & DOORS. KEEP PR OD OUT OF SEWERS & WATERCOURSES BY DIKING
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:"EMPTY" CNTNR WARNING. "EMPTY" CNTNRS
RETAIN RESIDUE (LIQ &/OR VAP) & CAN BE DANGEROUS. DO NOT ATTEMPT TO
CLEAN SINCE RESIDUE IS DFCLT TO REMOVE.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
GRIND/EXPOSE SUCH CNTNRS TO HEAT, FLAME, SPARKS, STATIC
ELECTRICITY, OR OTHER SOURCES OF IGNIT:THEY MAY EXPLODE & CAUSE
INJURY/DEATH. "EMPTY" DRUMS SHOULD BE COMPLETELY DRAINED, (ING 5)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:FIRES INVOLVING THIS TYPE OF PROD, DEPENDING ON
SIZE/POTNTL SIZE OF FIRE & CIRCUMSTANCES RELATED TO SITUATION. FIRE
FIGHT PROC:VAPS & TO PROVIDE PROT FOR MEN ATTEMPTING TO STOP LEAK.
WATE R SPRAY MAY BE USED TO FLUSH SPILLS AWAY FROM EXPOS.
SPILL/RELEASE PROC:OR IMPOUNDING. ADVISE AUTH IF PROD HAS (ING 3)

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:>357F,>176C
Vapor Pres:<3 @25C
Vapor Density:4.8
Spec Gravity:0.9
pH:NEUT
Evaporation Rate & Reference:<0.1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE (<0.1%)
Appearance and Odor:WATER-WHITE COLOR, MILD AROMATIC HYDROCARBON ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS SUCH AS LIQ CHLORINE, CONCENTRATED OXYGEN, SODIUM
HYPOCHLORITE/CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:UNDER FIRE CNDTNS:FUMES, SMOKE, CO,
ALDEHYES & OTHER DECOMP PRODS, IN CASE OF INCOMPLETE COMBUSTION.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.